亚洲中文字幕无码久久2020-巨胸爆乳美女露双奶头挤奶-欧美性xxxx极品少妇-中文字幕亚洲乱码熟女在线萌芽-疯狂做受xxxx高潮欧美日本-亚洲中文字幕日产乱码高清app

Tel:400-800-6106 WeChat Label Website map EN

Shenzhen NTEK Testing Technology Co., Ltd.

Current location : Home > Services> Product testing> Electrical and Electronic Product
?

Services

Contact us +

Hot Line 400-800-6106
NTEK Group
Tel:+8618923705875 Q Q:61827361 Email:ntek@ntek.org.cn Blocks C, D and E of Fenda Science and Technology Creative Park, Xixiang, Baoan District, Shenzhen

Home appliance testing and certification

Basic introduction

The North Testing Lab was authorized, and professional laboratories have been set up in Shenzhen, Dongguan, and Kunshan to provide "one-stop" services for small appliance testing and certification.

Product Range
Household appliances, power tools, adjustment controllers using semiconductor devices, electric motor-driven electrical, medical equipment, electric toys, vending machines, and movie or slide projectors.
Out of scope are:
In all other standards, clearly put forward all the equipment required for emission in its radio frequency range, such as lamps, grid communication devices, etc.
Regulation controller equipped with semiconductor device with rated input current greater than 25A per phase and equipment with such regulation controller;
Separate power supply, etc.

EU CE certification

Electromagnetic compatibility directive: 2004/108 / EC
Test standards: EN55014-1 (EMI), EN55014-2 (EMS), EN61000-3-2 (Harmonic), EN61000-3-3 (Flicker)
Note: The above-mentioned EN 61000-3-2 and EN 61000-3-3 are applicable to the input current of each phase of the equipment is less than 16A.

EMI part
Continuous harassment
Terminal voltage:
a Power terminal, frequency range: 0.15 ~ 30MHz; it is also divided into two kinds of limits for household appliances / similar equipment and power tools
b. Load terminals and additional terminals
Disturbance power:
Frequency range 30M ~ 300MHz limit and 30M ~ 300MHz frequency range "Margin" limit (this limit is one of the basis for judging whether to measure radiation disturbance)
Radiation harassment:
The frequency range is 30MHz ~ 1GHz; it is not necessary to test this item when the following two conditions are met at the same time:
a. The measurement value of disturbance power is less than the above-mentioned frequency range 30M ~ 300MHz limit value minus the value of 30M ~ 300MHz frequency range "Margin";
b. The maximum clock frequency is less than 30MHz. Otherwise you need to test this project.
Intermittent harassment
Clicking sound:
150KHz, 500KHz, 1.4MHz, 30MHz four frequency points, judge by upper quartile
Harmonic current
Standard: EN 61000-3-2
Products with a rated voltage range of AC220 ~ 240V need to be tested for this project
Unlimited value for products with rated power of 75W and below, no test required
Voltage fluctuation, flicker
Standard: EN 61000-3-3
Products with a rated voltage range of AC220 ~ 240V need to be tested for this project;
Limit requirements: short-term flicker value Pst≤1.0
Long-term flicker value Plt≤0.65
D (t) ≤500ms for a time exceeding 3.3% during a voltage change
Relative steady state voltage change dc≤3.3%
The maximum corresponding voltage change dmax is divided into three types: 4%, 6%, 7%

EMS part
Product Categories
Category 1: Appliances without electronic control circuits
Category 2: Transformer toys with electronic control circuits, dual power toys, electric appliances powered by mains, electric tools, electric heating appliances and similar appliances (such as ultraviolet radiation meters, infrared radiation meters and microwave ovens), The internal clock frequency or oscillation frequency does not exceed 15MHz.
Category 3: Appliances with electronic control circuits and powered by batteries (internal or external batteries). Under normal use conditions, this type of appliance is not connected to the mains, and the internal clock frequency or oscillation frequency of its electronic control circuit does not exceed 15MHz.
Category 4: All other appliances within the scope of this standard

EMS performance criteria
Performance criterion A
During the test, the appliance shall continue to operate as intended. When the appliance is used as intended, its reduced performance or loss of function must not be lower than the performance level (or allowable loss of performance) specified by the manufacturer. If the manufacturer does not specify a minimum level of performance or allowable loss of performance, it can be inferred from product specifications, documentation, and the user's reasonable expectations of the appliance when intended for use.
Performance criterion B
After the test, the appliance shall continue to operate as expected. When the appliance is used as intended, its reduced performance or loss of function must not be lower than the performance level (or allowable loss of performance) specified by the manufacturer. During the test, performance degradation is allowed, but the actual operating state or stored data is not allowed to change. If the manufacturer does not specify a minimum level of performance or allowable loss of performance, it can be inferred from product specifications, documentation, and the user's reasonable expectations of the appliance when it is used as intended.
Performance criterion C
Temporary loss of function is allowed, as long as this function can be restored by itself, or it can be restored by operating the controller or operating according to the instruction manual.

US FCC certification

Certification form: FCCVerification
Detection standard: FCC 47CFR Part 15B
Test items (only EMI part):
Item Frequency range
Power side conduction (CE) 0.15 ~ 30MHz
Space radiation (RE) 30MHz ~ 1GHz
Note: FCC certification, some home appliances are exempt.

China CCC certification

Testing standards: GB4343.1, GB17625.1
Test items:
Terminal voltage Frequency range: 0.15 ~ 30MHz
Disturbance power Frequency range 30M ~ 300MHz
Radiation disturbance Frequency range 30MHz ~ 1GHz (applicable to toys only, different from CE certification)
Click sound 150K, 500K, 1.4M, 30MHz four frequency points
Harmonic current Standard: GB17625.1
Products with a rated voltage range of AC220 ~ 240V need to be tested for this item; products with a rated power of 75W and below have unlimited value regulations, no testing is required.

Australian RCM certification

Detection standard: AS / NZSCISPR 14.1
Test items:
Terminal voltage Frequency range: 0.15 ~ 30MHz
Disturbance power Frequency range 30M ~ 300MHz
Radiation disturbance Frequency range 30MHz ~ 1GHz (Whether the radiation measurement is the same as CE certification)
Click sound 150K, 500K, 1.4M, 30MHz four frequency points

Japan PSE certification

Japan PSE certification: diamond and round PSE
Detection standard: J55014-1
Test items (only EMI part):
Terminal voltage Frequency range: 0.15 ~ 30MHz
Disturbance power Frequency range 30M ~ 300MHz
Click sound 150K, 500K, 1.4M, 30MHz four frequency points

Taiwan BSMI certification

Detection standard: CNS13783-1
Test items (only EMI part):
Terminal voltage Frequency range: 0.15 ~ 30MHz
Disturbance power Frequency range 30M ~ 300MHz
Radiation disturbance Frequency range 30MHz ~ 1GHz (Whether the radiation measurement is the same as CE certification)
Click sound 150K, 500K, 1.4M, 30MHz four frequency points

Obtaining quotations

Corporate name: *
Your name:*
Your cell phone and E-mail:*
Your needs:*

*For your benefit, your information will be kept strictly confidential

Submit successfully

Professional engineers will contact you quickly to provide you with appropriate solutions and look forward to meeting you~

Official account WeChat
主站蜘蛛池模板: 欧美一级在线免费| 2017最新h无码动漫| 蜜臀av免费一区二区三区| www国产无套内射com| 亚洲福利网| 少妇人妻偷人精品无码视频新浪| 国产精品高清在线| 欧美日韩一区在线| 国产乱子夫妻xx黑人xyx真爽 | 欧美一级高清免费| 97超视频在线观看| 顶级少妇做爰视频在线观看| 日本午夜精品一区二区三区电影| 无码日韩精品一区二区免费暖暖| 精品久久久久久久| 91亚洲国产成人精品性色 | 成人人观看的免费毛片| 国产做a| 亚洲一区二区三区国产精华液| 熟女人妇 成熟妇女系列视频| 2021最新国产精品一区| 日韩精品 电影一区 亚洲| 国产精品交换| 在线看免费观看日本| 日韩人妻熟女中文字幕a美景之屋| 久久亚洲精品国产亚洲老地址| 久操网站| 亚洲国产精品久久久| 亚洲三级视频在线观看| 精品一区二区三区东京热| 日本在线观看| 无码孕妇孕交在线观看| 国产成人系列| 中文字幕专区| 91免费观看| 欧美精品一区二区三区免费播放| 国产精品视频全国免费观看| 22eee在线播放成人免费视频| 欧美性猛交xxxxx按摩欧美| 久久国产欧美日韩精品| 性生交大全免费看|